Lifesaving equipment maintenance instructions

The ship shall do a good job of maintaining the fire protection and maintenance of the lifesaving equipment in accordance with the requirements of this Notice, and make it available at all times, and periodically test and inspect it to maintain its intact state so as to ensure that it can play the required role in the event of fire or lifeboat. .
I. Fire detection and alarm devices
Strictly follow the inspection cycle to carry out the correct test to ensure that the alarm is in good condition at any time.
1. The manual alarm device should be tested every week.
2. The automatic fire detection alarm device shall be tested for utility every quarter.
Two. Fixed test gas (CO2) fire extinguishing system
1. Routine inspections are conducted every quarter, with the responsibility of three crews. The chief of the crew assists. The content is the ventilation of the station room cylinders, communication equipment and alarm devices.
2. All pipelines shall be air-passed with a pressure of 0.5 MPa every 2 years; air-tightness tests shall be conducted with a pressure of at least 0.5 MPa every 4 to 5 years; pressure shall be applied from the bottle head valve to the distribution valve box section in 8 to 10 years. The hydraulic test for 11.8Mpa. After the road hydraulic test, the body flow should be eliminated.
3. The pressure test shall be conducted every five years for the piping system (from the distributing valve to the sprinkler section). Three teams shall be responsible for the certification of the professional organization.
4. Perform an internal inspection every 8 to 10 cylinders.
5. The bottle valve should be subjected to hydraulic test with a test pressure of 24.5Mpa.
3. Portable type. Cart fire extinguisher
1. Maintenance cycle: The regular maintenance interval is 6 months. After the ship is repaired, it should be maintained after the storm and after the fire.
2. Maintenance standards
2.1 Quantity: Meet the requirements of the ship's fire control plan.
2.2 Storage: The position and its number are in line with the ship's fire control map, the signs are clear, there is a fixed storage rack, to prevent shaking, tilting and impact. The surrounding channels are clear, so as to extract and use, should not prevent the extraction of things. To prevent overheating or exposure. (Foam extinguisher sunscreen, antifreeze).
2.3 Clean: No dust and oil, no rust on the shell, marked.
2.4 release device: the nozzle is open, the rust-free insurance pin, active.
2.5 Each fire extinguisher inspection card shall be established and recorded as required.
4. Firefighters' Equipment
Firefighter equipment
1.1 Firefighters' equipment should be placed in a dry, ventilated place at ordinary times to prevent mildew and rust. The inspection should be conducted every three months to ensure cleanliness and lightness.
1.2 Seat belts and safety hooks shall be checked by three persons for tensile load. If any damage or high temperature, open flame, strong acid, alkali or other corrosion is found, it shall be replaced in a timely manner; if there is dirt scrubbing with soapy water, then rinse with water to dry, but not Permits immersion in boiling water and exposure to fire.
2. Air respirator
2.1 After using the air respirator, it should be cleaned, disinfected and airtightly checked in time.
2.2 Replace cylinders with sufficient air.
2.3 The air respirator shall not be subject to pressure, sun exposure and poisonous gas erosion.
2.4 Each respirator should be equipped with a spare air bottle (special ship equipped with special provisions)
2.5 Each month of the contingency exercise should be checked once. The content includes:
1. Air bottle pressure should meet the requirements;
2. The respirator is neat;
3. Respirators are airtight and unobstructed;
4. All equipment is in good condition;
5. There is a spare air bottle.
3. The maintenance inspections of firefighters' equipment are the responsibility of the three teams and records are made.

Metallized Ceramic Ring is always used as a ceramic insulator, ceramic washer at ceramic to metal jointing application.


The most popular metallization is ceramic body with Mo/Mn metallization, then with nickle plating. Of course, other different metallic coating is available to supply, like silver plating, gold plating, tin plating and so on.


We have very high precision flating grinding, cylinderical grinding, glazing capability in our production. We are are able to offer extreme thin wall thickness ceramic ring with min. 0.8mm, the roundness and flatness can be controlled to be ideal level beyond clients' expectation.

Metallized Ceramic Ring

Metallized Ceramic Ring,Large Size Ceramic Metallization Ring,Metallization Ceramic Threaded Ring,Industrial Metallized Ceramic Rings

Jinghui Industry Ltd. , https://www.ceramictek.com