Detailed description of the structure of heat-conducting oil pump

RY-type heat transfer oil pump structure: RY-type horizontal heat transfer oil pump for the single-stage cantilever structure, the pump inlet for the axial suction, the outlet for the center vertical upward. The pump and drive motor are mounted on the same base by flexible couplings. The whole machine without external cooling system. Import and export of pumps flange connection, the pressure parts are produced by the pressure of 16bar class, the base size in line with the provisions of GB5662. The main components of the thermal oil pump structure is assembled as follows: 1. Pump shell part: the pump body, pump cover. 2. Rotor part: an impeller, shaft, impeller nut composition. 3. Bearing part: bearing unit installed in the two high-speed bearings, rotor support body. 4. Sealing part: the use of carbon fiber packing and PTFE seal with the use. 5. Transmission parts: Pump and motor with three-jaw type elastic coupling or belt coupling, the motor uses an ordinary motor or explosion-proof motor.