Seamless Steel Pipe for Structure or Fluid Transportation

Trademark: hualite
Transport Package: Bundle
Specification: OD range from 25mm to 960mm
Origin: China
HS Code: 7304191000
Trademark: hualite
Transport Package: Bundle
Specification: OD range from 25mm to 960mm
Origin: China
HS Code: 7304191000

Seamless Steel Pipe for Structure or Fluid Transportation
Seamless Steel Pipe for Structure or Fluid Transportation


Hualite specializes in the supply of Line Pipe in Seamless and Welded manufacture used for construction of long distance pipelines to transport oil and gas, heating systems and general purpose conditions. We also cater to the needs of Petrochemical and Power Generation Plants, Rig and Ship Building Industries, Construction and General Engineering Sectors offering high quality tubes in a variety of material grades, sizes and wall thickness primarily from stock or short lead times.

Size and Grade as following:
 

Outside Diameter (mm) Φ60-Φ114-Φ127-Φ159-Φ219-Φ245-Φ273-Φ299-Φ325-Φ351-Φ377-Φ402-Φ406-Φ426Φ457
Thickness (mm) 4-14,4-25,5-27,6.5-40,8-50,9-50,10-60
Steel Grade 10#,20#,35#,45#,16Mn,Q345(B,C,D,E),P11,P12,12CrMo ,12Cr1MoV,12Cr1MoVG, 15CrMo,15CrMoG,20G,27SiMn,34CrMo4,35CrMo,30CrMo,34Cr,A333Gr.3,A-106B,35Cr-1,34CrMo4-1,37Mn,30MnNbRe
Standard GB3087,GB/T8162,GB/T8163 ,GB5310-1995,A106,A333,A36M,A53M, A387M,A335M,A370,A530

Seamless Steel Pipe for Structure or Fluid Transportation
Seamless Steel Pipe for Structure or Fluid Transportation


Hualite specializes in the supply of Line Pipe in Seamless and Welded manufacture used for construction of long distance pipelines to transport oil and gas, heating systems and general purpose conditions. We also cater to the needs of Petrochemical and Power Generation Plants, Rig and Ship Building Industries, Construction and General Engineering Sectors offering high quality tubes in a variety of material grades, sizes and wall thickness primarily from stock or short lead times.

Size and Grade as following:
 

Outside Diameter (mm) Φ60-Φ114-Φ127-Φ159-Φ219-Φ245-Φ273-Φ299-Φ325-Φ351-Φ377-Φ402-Φ406-Φ426Φ457
Thickness (mm) 4-14,4-25,5-27,6.5-40,8-50,9-50,10-60
Steel Grade 10#,20#,35#,45#,16Mn,Q345(B,C,D,E),P11,P12,12CrMo ,12Cr1MoV,12Cr1MoVG, 15CrMo,15CrMoG,20G,27SiMn,34CrMo4,35CrMo,30CrMo,34Cr,A333Gr.3,A-106B,35Cr-1,34CrMo4-1,37Mn,30MnNbRe
Standard GB3087,GB/T8162,GB/T8163 ,GB5310-1995,A106,A333,A36M,A53M, A387M,A335M,A370,A530

High Purity Water System

Purified water System One of the basic considerations in the design of a system is the type of product that is to be manufactured. For parenteral products where there is a concern for pyrogens, it is expected that Water for Injection will be used. This applies to the formulation of products, as well as to the final washing of components and equipment used in their manufacture. Distillation and Reverse Osmosis (RO) filtration are the only acceptable methods listed in the USP for producing Water for Injection. However, in the bulk Pharmaceutical and Biotechnology industries and some foreign companies, Ultra Filtration (UF) is employed to minimize endotoxins in those drug substances that are administered parenterally.

For some ophthalmic products, such as the ophthalmic irrigating solution, and some inhalation products, such as Sterile Water for Inhalation, where there are pyrogen specifications, it is expected that Water for Injection be used in their formulation. However, for most inhalation and ophthalmic products, purified water is used in their formulation. This also applies to topicals, cosmetics and oral products.

Another design consideration is the temperature of the system. It is recognized that hot (65 – 80℃) systems are self sanitizing. While the cost of other systems may be less expensive for a company, the cost of maintenance, testing and potential problems may be greater than the cost of energy saved.

Whether a system is circulating or one-way is also an important design consideration. Obviously, water in constant motion is less liable to have high levels of contaminant. A one-way water system is basically a "dead-leg".

Finally, and possibly the most important consideration, is the risk assessment or level of quality that is desired. It should be recognized that different products require different quality waters. Parenterals require very pure water with no endotoxins. Topical and oral products require less pure water and do not have a requirement for endotoxins. Even with topical and oral products there are factors that dictate different qualities for water. For example, preservatives in antacids are marginally effective, so more stringent microbial limits have to be set. The quality control department should assess each product manufactured with the water from their system and determine the microbial action limits based on the most microbial sensitive product. In lieu of stringent water action limits in the system the manufacturer can add a microbial reduction step in the manufacturing process for the sensitive drug product(s).

High Purity Water System,Injection purified water system,Pharmaceutical ultrapure water systems,Laboratory ultrapure water system