Use and maintain dosing pump back pressure valve method

1. Used to prevent the gravity flow of gravity under gravity (or siphon), this time generally greater than the pressure of the liquid itself can be used, such as to prevent the liquid level of 2 meters medicine tank gravity, the pressure can be greater than 0.02MPa back pressure Valve, the general metering pump can be used 0.1MPa. 2. Used to stabilize the metering pump flow, such as some metering pump flow with the pressure changes larger, can be set in the metering pump outlet back pressure valve, the metering pump output flow stability, then generally choose back pressure valve The pressure for the metering pump actual use pressure or slightly less than the metering pump working pressure. 3. The check valve on the outlet pipe is used to prevent liquid back-flow and the back-pressure valve is used to keep the metering pump outlet at a constant pressure. Due to the reciprocating movement of the metering pump, the driving part has a certain impact sound is normal phenomenon, GB / T7782-1996 "metering pump" provisions in the distance of 1 meter from the pump is not the noise of 75 dB (of course, the smaller the better), abnormal sound , The following may be caused by the following reasons: a. The pressure of the pump exceeds the rated pressure of the pump (This phenomenon may occur when the check valve on the pipe is not clear. You can install a pressure gauge at the outlet of the metering pump to the check valve to check the outlet pressure of the metering pump ). b. Worm bearing damage.